Basic Info.
Energy Efficiency Grade
One
Heat Temperature
7~55 Deg C
Work Environment
Common Heat Pump
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, SASO
Compressor
Copeland/Panasonic
Power Supply
220V/50Hz, 1 Phase
Transport Package
Wooden Case
Product Description
MES Commercial water source heat pumps for cooling and heating
This is water source heat pumps commercial use for cooling and heating, it is usually installed in area where weather very cold in winter, and in summer it can also supply chilled water for cooling.
We only use the best quality and famous brand parts for assembling and all the testing for the heat pump parts and heat pump units will be finished by expert workers and engineers with professional equipment.
Product Info.
Compressor | Copeland scroll or Panasonic scroll |
Capacity | 11KW,17KW,24KW,34KW,48KW,68KW,80KW, 120KW,160KW |
Refrigerant | R410A |
Condenser | "ND" shell and tube heat exchanger |
Evaporator | Shell & tube, tube in tube or plate type heat exchanger |
AC contactor & Relay | Schneider |
Electronic expansion valve | Japan Saginomiya or World No.1 Sanhua |
Controller | LCD |
Package | Wooden case or Carton |
Fasteners | Stainless steel 304 |
Additional Info.
Delivery time | 25 days after order confirmed |
Warranty time | 24 months after shipment |
Payment term | T/T or L/C at sight |
Production capacity | 400 units per month |
Brand | MES or OEM |
WHY US?
Components we use:
BEST DESIGN FOR BEST OPERATION!
PRODUCT FEATURES:
a. Copeland and R410a refrigerant for best operation.
b. Shell & tube heat exchanger, tube in tube heat exchanger, plate type heat exchanger for option;
c. Emergency switch for power on/off.
d. World famous brands of components, such as Saginomiya electronic expansion valves, SHF 4-way valves and etc.,
e. With compelete testing in laboratory for good quality and highest COP.
f. All copper material for water pipes.
g. Strong wooden case packing for safe sea transporation.
h. Advanced control system for reaching all of your requirements, such as Rs485, PC connection, Modbus port.
i. Unique cabinet designing, for your better marketing.
Parameters table:
| CL11s-CW5 | CL17s-CW5 | CL11-CW5 | CL17-CW5 | CL24-CW5 | CL34-CW10 | CL48-CW10 | CL68-CW20 | CL80-CW20 | CL120-CW20 | CL160-CW20 |
Underground water open loop | Rated cooling capacity | KW | 11 | 17 | 11 | 17 | 24 | 34 | 48 | 68 | 80 | 120 | 160 |
Rated input power for cooling | KW | 2.15 | 3.34 | 2.11 | 3.20 | 4.72 | 6.53 | 9.18 | 13.18 | 15.72 | 23.35 | 31.56 |
Rated input current for cooling | A | 9.55 | 14.84 | 3.98 | 6.04 | 8.91 | 12.33 | 17.35 | 24.91 | 29.71 | 44.12 | 59.64 |
Cooling performance coefficient (EER) | / | 5.12 | 5.09 | 5.22 | 5.32 | 5.09 | 5.21 | 5.23 | 5.16 | 5.09 | 5.14 | 5.07 |
Rated heating capacity | KW | 9.5 | 16 | 9.5 | 16 | 22 | 32 | 45 | 65 | 75 | 115 | 150 |
Rated input power for heating | KW | 2.59 | 4.38 | 2.59 | 4.31 | 6.09 | 8.86 | 12.33 | 18.01 | 21.01 | 32.39 | 41.78 |
Rated input current for heating | A | 12.33 | 20.87 | 4.89 | 8.15 | 11.52 | 16.75 | 23.30 | 34.03 | 39.71 | 61.23 | 78.97 |
Heating performance coefficient (COP) | / | 3.67 | 3.65 | 3.67 | 3.71 | 3.61 | 3.61 | 3.65 | 3.61 | 3.57 | 3.55 | 3.59 |
Application side heat exchanger water flow | M3/h | 1.89 | 2.92 | 1.89 | 2.92 | 4.13 | 5.85 | 8.26 | 11.70 | 13.76 | 20.64 | 27.52 |
Heat source side heat exchanger water flow | M3/h | 1.03 | 1.59 | 1.03 | 1.59 | 2.25 | 3.19 | 4.50 | 6.38 | 7.51 | 11.26 | 15.01 |
Ground source closed loop | Rated cooling capacity | KW | 10 | 16 | 10 | 16 | 22 | 32 | 46 | 64 | 76 | 114 | 150 |
Rated input power for cooling | KW | 1.96 | 3.17 | 1.95 | 3.13 | 4.38 | 6.17 | 8.83 | 12.48 | 14.90 | 22.27 | 29.64 |
Rated input current for cooling | A | 8.70 | 14.11 | 3.68 | 5.91 | 8.28 | 11.65 | 16.69 | 23.58 | 28.16 | 42.08 | 56.03 |
Cooling performance coefficient (EER) | / | 5.11 | 5.04 | 5.13 | 5.12 | 5.02 | 5.19 | 5.21 | 5.13 | 5.10 | 5.12 | 5.06 |
Rated heating capacity | KW | 8 | 12 | 8 | 12 | 16 | 24 | 33 | 48 | 57 | 86 | 115 |
Rated input power for heating | KW | 3.07 | 4.43 | 3.04 | 4.58 | 5.99 | 9.20 | 12.60 | 18.39 | 22.01 | 32.95 | 43.73 |
Rated input current for heating | A | 13.27 | 19.17 | 5.66 | 8.52 | 11.15 | 17.10 | 23.43 | 34.21 | 40.93 | 61.29 | 81.33 |
Heating performance coefficient (COP) | / | 2.61 | 2.71 | 2.63 | 2.62 | 2.67 | 2.61 | 2.62 | 2.61 | 2.59 | 2.61 | 2.63 |
Application side heat exchanger water flow | M3/h | 1.38 | 2.06 | 1.38 | 2.06 | 2.75 | 4.13 | 5.68 | 8.26 | 9.80 | 14.79 | 19.78 |
Heat source side heat exchanger water flow | M3/h | 1.72 | 2.58 | 1.72 | 2.58 | 3.44 | 5.16 | 7.10 | 10.32 | 12.26 | 18.49 | 24.73 |
Power supply | 1N 220V/50Hz (Special power supply for option) | 3N 380V/50Hz(Special power supply for option) |
Compressor | Type | Hermetic scroll type |
Quantity | PCS | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 4 |
Heat source side heat exchanger | Type | Shell & coil(tube) heat exchanger |
Connection size | DN | DN20 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | DN80 |
Application side heat exchanger | Type | Shell & coil(tube) heat exchanger |
Connection size | DN | DN20 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | DN80 |
Protections | 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc. |
Refrigerant | Type | R410A |
Quantity | KG | 2.6 | 3.3 | 2.6 | 3.3 | 4.2 | 3.3x2 | 4.2x2 | 6.6x2 | 7.6x2 | 7.6x3 | 7.6x4 |
Dimension | mm | 790x415x590 | 790x710x950 | 2000x1000x1600 |
Wooden case package dimensions(L*W*H) | mm | 836x461x752 | 836x756x1112 | 2056x1056x1768 |
Net weight | KG | 68 | 95 | 65 | 95 | 135 | 195 | 320 | 795 | 885 | 1180 | 1210 |
Gross weight | KG | 78 | 105 | 75 | 105 | 145 | 215 | 340 | 830 | 920 | 1215 | 1245 |
Noise | DB(A) | ≤53 | ≤55 | ≤55 | ≤55 | ≤58 | ≤58 | ≤62 | ≤65 | ≤70 | ≤75 | ≤75 |
Note: |
1. Underground water open loop type cooling standard condition: application side water input/output temperature 12ºC/7ºC; source side water input/output temperature 18ºC/29ºC. Underground water open loop type heating standard condition: application side water input/output temperature 40ºC/45ºC; source side water input/output temperature 15ºC/-a. |
2. Ground source closed loop type cooling standard condition: application side water input/output temperature 12ºC/7ºC; source side water input/output temperature 25ºC/30ºC Ground source closed loop type heating standard condition: application side water input/output temperature 40ºC/45ºC ; source side water input/output temperature 5ºC/-a. |
3. "-a " means the water flow under cooling standard condition. |
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret. |
Welcome to MES!
Address:
West Of Dayang Bridge, Novth Of Huhang Road, Fouth Graup Of Dong Fang Huage, Ganpu Town, Haiyan County
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 14000
Company Introduction:
MES has focused on all kinds of heat pumps with professional and complete producing line, laboratory, expert R&D team, installation team and after sales service team. With its professional team and focusing on heat pump development, it has been known as good quality and excellent service.
All of the workers have been highly trained and most of them have been worked in this field for more than 5 years, with the professional producing equipment, MES is one of the highest quality heat pumps supplier in China.
MES is not only a manufacturer, but also a solution supplier for customers all around the world. With the engineers who have more than 10 years experiences, it is supplying installation advice, troubleshooting and maintenance solutions for customers.
MES has customers for both domestic and overseas market, with the experienced salesman, communication will be very easy.
Its main products as below:
1. Air source heat pumps for home and commercial use,
2. Water source heat pumps,
3. House heating heat pumps,
4. Cooling and heating heat pumps,
5. Swimming pool heat pumps.
Moreover, besides standard products, MES also research and develop an extensive range of customized products to meet different requests from customers.
Heat pumps can be applied for your home for sanitary hot water, or room cooling and heating, it can also been installed for hot water or cooling and heating for hotels, schools, hospitals and so on.
MES is the first factory who supply 2 years warranty time for the heat pump and 3 years warranty time for compressor and condenser, as it has the confidence to supply the best products and services to its customers.
MES will be a super good choice for your heat pumps business, with your help, let us create a green planet together.